Benchmark test for RIOT timers
This test is intended to collect statistics about the runtime delays in the periph_timer implementation. This tool is mainly intended to detect problems in the low level driver implementation which can be difficult to detect from higher level systems such as xtimer.
Testing periph/timer
The basic idea of the test is to generate a wide variety of calls to the periph/timer API, in order to detect problems with the software implementation. The test consists of a single thread of execution which will set random timeouts on a periph_timer device. A reference timer is used to measure the time it takes until the callback is called. The difference between the expected time and the measured time is computed, and the mean and variance of the recorded values are calculated. The results are printed as a table on stdout every 30 seconds. All of the test scenarios used in this application are based on experience from real world bugs encountered during the development of RIOT and other systems.
periph/timer functions tested
Both timer_set and timer_set_absolute calls are mixed in a random order, to ensure that both functions are working correctly.
Rescheduling
Some bugs may occur only when the application attempts to replace an already set timer by calling timer_set again while the timer is running. This is dubbed "resched" in this application. The application will issue rescheduling timer calls in the normal operation of the test to catch this class of problems.
Setting stopped timers
Another class of bugs is the kind where a timer is not behaving correctly if it was stopped before setting a timer target. The timer should set the new target, but not begin counting towards the target until timer_start is called. This is covered by this application under the "stopped" category of test inputs.
General benchmark behaviour
The benchmark application uses some techniques to improve the quality of the tests.
Avoiding phase lock
The CPU time used for generation and setting of the next timer target in software is approximately constant across iterations. When the application flow is driven by the timer under test, via a mutex which is unlocked from the timer callback, the application will be "phase locked" to the timer under test. This peculiarity may hide certain implementation race conditions which only occur at specific phases of the timer ticks. In the test application, this problem is avoided by inserting random CPU delay loops at key locations:
- After timer_stop
- Before timer_set/timer_set_absolute
- Before timer_start
Estimating benchmark CPU overhead
An estimation of the overhead resulting from the CPU processing delays inside the benchmarking code is performed during benchmark initialization. The estimation algorithm attempts to perform the exact same actions that the real benchmark will perform, but without setting any timers. The measured delay is assumed to originate in the benchmark code and will be subtracted when computing the difference between expected and actual values. A warning is printed when the variance of the estimated CPU overhead is too high, this can be a sign that some other process is running on the CPU and disrupting the estimation, or a sign of serious problems inside the timer_read function.
Testing xtimer
The benchmark application can be reconfigured for using xtimer instead of the low level periph/timer interface. Use the Makefile target test-xtimer to build a test for xtimer.
xtimer functions tested
The application will mix calls to the following xtimer functions:
_xtimer_set
_xtimer_periodic_wakeup
_xtimer_spin
These functions cover almost all uses of xtimer. The higher level functions
such as xtimer_usleep
and xtimer_set_msg
all use these functions internally
in the implementations.
Results
When the test has run for a certain amount of time, the current results will be presented as a table on stdout. To assist with finding the source of any discrepancies, the results are split according to three parameters:
- Function used: timer_set, timer_set_absolute
- Rescheduled: yes/no
- Stopped: yes/no
Expected results
It is difficult to set a general expected result which applies to all platforms. However, the mean and variance of the differences should be small, in relation to the tick duration of the timer under test. What is "small" also depends the CPU core frequency, because of CPU processing time spent in the driver code and in the test code. For example, when testing a 1 MHz timer and comparing with another 1 MHz timer, the mean difference should likely be in single digits on a Cortex-M CPU. Testing a 32768 Hz timer and referencing a 1 MHz timer on the other hand should have a mean difference in double digits, the variance will also be greater because of the quantization errors and rounding in the tick conversion routine. If the mean or variance of the difference is exceptionally large, the row will be marked with "SIC!" to draw attention to the fact.
Interpreting timer_set_xxx statistics
The first part of the results compares the reference time elapsed against the expected time. A negative value means that the timer alarm is triggered too soon, compared to the expected time. A positive value means that the timer alarm is triggered late, compared to the expected time.
Expected variance
The variance of the results should generally be as small as possible, except for the case where the reference timer is running at a higher frequency than the timer under test. There will always be a truncation error when setting a timer target because of the discrete timer counts that can be set. The benchmark will compute limits for the expected variance and show a message if the variance is less than or greater than the expected variance.
Variance too low
A variance lower than expected indicates that there is a phase correlation between the reference timer and the timer under test. This can only be explained by a software bug or a hardware failure. The primary suspect will be the reference timer.
Variance too high
A variance greater than expected indicates that there is some extra randomness in the timeout length, which can be caused by other processes interfering with the test, a software bug in the timer under test, or hardware failure.
Mathematical explanation
Let X0
be the exact time that a timer_set call occurs, X0
is a real number.
Let T
be the desired timeout, T
is a positive integer because the timer can
only count integer number of ticks. Let x0 = floor(X0)
be the count that the
timer is currently on when the timer is set, x0
is an integer. If X0
is
uniformly random, then the truncation error X0' = (X0 - x0)
will be a sample
from a continuous uniform distribution in the interval [0,1)
ticks. The timer
target, x1
, in the timer under test can be expressed as x1 = x0 + T
. Let
k
be a real number that satisfies Y = kx
, where x
is an interval in the
unit used by the timer under test, and Y
is an interval in the unit used by
the reference timer, Y
is a real number. The time measured by the reference
timer can be expressed as
Y = k(x1 - X0) = k(x0 + T - X0) = k(X0 - X0' + T - X0) = k(T - X0')
.
Y
will be a sample from a uniform random distribution in the interval
[kT, k(T + 1)]
. The variance of Y
is defined as
Var(Y) = (k(T + 1) - kT)^2 / 12
.
Interpreting timer_read statistics
A separate table is displayed for statistics on timer_read. This table compares
the expected timer under test time after a timer has triggered, against the
actual reported value from timer_read(TIM_TEST_DEV)
. A positive value means
that the TUT time has passed the timer target time. A negative value means
that, according to the timer under test, the alarm target time has not yet been
reached, even though the timer callback has been executed.
A note on BOARD=native
When running on native, the application will be running as a normal process in a multi process system which means that most results will have a much greater variance than expected and the resulting differences will also be much larger than on a bare metal system. Be careful when drawing conclusions on results from native.
Configuration
The timer under test and the reference timer can be chosen at compile time by defining TIM_TEST_DEV and TIM_REF_DEV, respectively. The frequencies for these timers can be configured through TIM_DEV_FREQ and TIM_REF_FREQ. For example, to compare timer device 2 running at 32768 Hz against a reference timer on timer device 0 (default) running at 1 MHz (default) on Mulle:
CFLAGS='-DTIM_TEST_DEV=TIMER_DEV\(2\) -DTIM_TEST_FREQ=32768' BOARD=mulle make flash
Default configuration
reference timer: TIMER_DEV(0) timer under test: TIMER_DEV(1) timer frequency: 1 MHz
Define USE_REFERENCE=0 to compare a timer against itself. Be aware that this may hide a class of errors where the timer is losing ticks in certain situations, which a separate reference timer would be able to detect.
Example output
Below is a short sample of a test of a 32768 Hz timer with a 1 MHz reference:
------------- BEGIN STATISTICS --------------
Limits: mean: [-10, 41], variance: [58, 99]
Target error (actual trigger time - expected trigger time), in reference timer ticks
positive: timer is late, negative: timer is early
=== timer_set running ===
interval count sum sum_sq min max mean variance
1 - 2: 25705 455646 2002373 2 35 17 77
3 - 4: 25533 457326 1973191 2 35 17 77
5 - 8: 25412 451046 1970014 2 35 17 77
9 - 16: 25699 458563 2017198 2 36 17 78
17 - 32: 25832 457768 2018909 1 35 17 78
33 - 64: 25758 440454 1978830 1 35 17 76
65 - 128: 25335 414320 1942196 0 34 16 76
129 - 256: 25254 367689 1979616 -3 32 14 78
257 - 512: 25677 285822 2020736 -7 31 11 78
TOTAL 230205 3788634 18459378 -7 36 16 80
...
The statistics above show that the timer implementation introduces a small delay on short timers. Note however that it is not clear whether this delay is in timer_set, or timer_read, but the combined effect of all error sources make the timer overshoot its target by on average 17 microseconds. The difference between min and max is close to the expected difference of approximately 1/32768 s = 30.51 µs. The lower min and mean for the longer timer intervals are most likely caused by a drift between the 1 MHz clock and the 32.768 kHz clocks inside the CPU, and is expected when using two separate clock sources for the timers being compared.
Below is a short sample of a test where there is something wrong with the timer implementation, again a 32768 Hz timer tested with a 1 MHz reference:
=== timer_set_absolute resched ===
interval count sum sum_sq min max mean variance
1 - 2: 152217 82324291 13339518497 38 1071 540 87635 <=== SIC!
3 - 4: 152199 82254909 13301794832 38 1071 540 87397 <=== SIC!
5 - 8: 152023 82085454 13264873203 38 1071 539 87256 <=== SIC!
9 - 16: 152156 82236539 13265351119 38 1071 540 87183 <=== SIC!
17 - 32: 152639 82606815 13267666812 38 1071 541 86922 <=== SIC!
33 - 64: 151883 81836155 13268661551 37 1070 538 87361 <=== SIC!
65 - 128: 152114 82151495 13228100922 36 1070 540 86962 <=== SIC!
129 - 256: 152363 81806042 13278055359 34 1069 536 87148 <=== SIC!
257 - 512: 152360 81235185 13303811951 29 1066 533 87318 <=== SIC!
TOTAL 1369954 738536885 119197349719 29 1071 539 87008 <=== SIC!
We can see that the variance, the maximum error, and the mean are very large. This particular timer implementation needs some work on its timer_set_absolute implementation.
Configuration details
Configuration macros used by the application are described below
Settings related to timer hardware
TIM_TEST_DEV
Timer under test. Default: TIMER_DEV(1)
TIM_REF_DEV
Reference timer used for measuring the callback time error. Default: TIMER_DEV(0)
TIM_TEST_FREQ
Frequency of the timer under test, used when calling timer_init during the
application startup. Default: 1000000
, 1 MHz
TIM_REF_FREQ
Frequency of the reference timer, used when calling timer_init during the
application startup. Default: 1000000
, 1 MHz
TIM_TEST_CHAN
Timer channel used on the timer under test. Default: 0
USE_REFERENCE
Shorthand for setting the reference timer to the same as the timer under test.
Default: 0
Settings related to result processing
DETAILED_STATS
Keep statistics per timer target offset value if set to 1, otherwise keep
statistics only per scenario. Default: 1
LOG2_STATS
Only used when DETAILED_STATS == 1
. Statistics are grouped according to
2-logarithms of the timer offset value, e.g. 1-2, 3-4, 5-8, 9-16 etc. This
reduces memory consumption and creates a shorter result table for easier
overview. Default: 1
TEST_PRINT_INTERVAL_TICKS
The result table will be printed to standard output when this many reference
timer ticks have passed since the last printout. Default: ((TIM_REF_FREQ) * 30)
Settings related to timer input generation
TEST_MIN
Minimum timer offset tested for timer_set_absolute
, in timer under test
ticks. Default: 1
for timers < 1 MHz, 16
otherwise, to prevent setting a
timer target in the past
TEST_MIN_REL
Minimum timer offset tested for timer_set
, in timer under test ticks.
Default: 0
TEST_MAX
Maximum timer offset tested, in timer under test ticks. Default: 128
SPIN_MAX_TARGET
The CPU busy wait loop will be calibrated during application start up so that
the maximum random spin length is approximately equal to this many timer under
test ticks. Default: 16
TEST_UNEXPECTED_STDDEV
Mark the output row if the computed variance implies a standard deviation which
is greater than this value. This value will be automatically recomputed to
compensate for the variance resulting from the truncation in the tick
conversion if the reference timer is running at a higher frequency than the
timer under test. Default: 4
TEST_UNEXPECTED_MEAN
Mark the output row if the computed mean absolute difference is greater than this
number of timer under test ticks. This value will be automatically recomputed
to compensate for the error resulting from the truncation in the tick
conversion if the reference timer is running at a higher frequency than the
timer under test. Default: 2