* Copyright (C) 2021 ML!PA Consulting GmbH
|
|
*
|
|
* This file is subject to the terms and conditions of the GNU Lesser
|
|
* General Public License v2.1. See the file LICENSE in the top level
|
|
* directory for more details.
|
|
*/
|
|
|
|
/**
|
|
* @ingroup drivers_lm75
|
|
*
|
|
* @{
|
|
* @file
|
|
* @brief Registers for the lm75 and derived (lm75a and tmp1075) temperature sensors.
|
|
*
|
|
* @author Vitor Batista <vitor.batista@ml-pa.com>
|
|
*/
|
|
|
|
#ifndef LM75_REGS_H
|
|
#define LM75_REGS_H
|
|
|
|
#ifdef __cplusplus
|
|
extern "C" {
|
|
#endif
|
|
|
|
/* LM75 register list */
|
|
#define LM75_TEMP_REG (0x00) /**< Temperature register pointer */
|
|
#define LM75_CONF_REG (0x01) /**< Configuration register pointer */
|
|
#define LM75_THYST_REG (0x02) /**< Hysteresis register pointer */
|
|
#define LM75_TOS_REG (0x03) /**< Overtemperature shutdown register pointer */
|
|
|
|
/* Device Operation mode */
|
|
#define NORMAL_MODE 0 /**< Continuous conversion mode */
|
|
#define SHUTDOWN_MODE 1 /**< Shutdown mode ON */
|
|
|
|
/* Device Thermostat operation mode */
|
|
#define COMPARATOR_MODE 0 /**< OS operation in comparator mode */
|
|
#define INTERRUPT_MODE 1 /**< OS operation in interrupt mode */
|
|
|
|
/* OS polarity */
|
|
#define OS_ACTIVE_LOW 0 /**< OS pin active on Low voltage */
|
|
#define OS_ACTIVE_HIGH 1 /**< OS pin active on positive voltage */
|
|
|
|
/* Consecutive fault measurements to trigger the alert function */
|
|
#define FAULT_1 0 /**< OS/ALERT active after 1 fault */
|
|
#define FAULT_2 1 /**< OS/ALERT active after 2 faults */
|
|
|
|
/* LM75A exclusive registers */
|
|
|
|
#define FAULT_4 2 /**< OS active after 4 faults */
|
|
#define FAULT_6 3 /**< OS active after 6 faults */
|
|
|
|
/* TMP1075 exclusive registers */
|
|
|
|
/* Device ID register - only available in the TMP1075 sensor */
|
|
#define TMP1075_DEVICE_ID_REG (0x0F) /**< ID register pointer */
|
|
|
|
/* fault queue values exclusive to the TMP1075 sensor */
|
|
#define FAULT_3 2 /**< ALERT active after 3 faults */
|
|
#define FAULT_4_TMP1075 3 /**< ALERT active after 4 faults */
|
|
|
|
/* Conversion rate setting when device is in continuous conversion mode
|
|
* Only configurable in the TMP1075 sensor */
|
|
#define TMP1075_CONV_RATE_REG_27H 0 /**< 27.5ms conversion rate */
|
|
#define TMP1075_CONV_RATE_REG_55 1 /**< 55ms conversion rate */
|
|
#define TMP1075_CONV_RATE_REG_110 2 /**< 110ms conversion rate */
|
|
#define TMP1075_CONV_RATE_REG_220 3 /**< 220ms conversion rate */
|
|
|
|
#ifdef __cplusplus
|
|
}
|
|
#endif
|
|
|
|
#endif /* LM75_REGS_H */
|
|
/** @} */
|