Marian Buschsieweke 3c287c058d
sys/phydat: Fix unit confusion
Previously, `UNIT_G` was used for g-force with the correct symbol `g`,
`UNIT_GR` for gram (as in kilogram) with the incorrect symbol `G` (which
would be correct for Gauss), and `UNIT_GS` for Gauss with symbol `Gs`
(which is an uncommon but correct symbol).

To avoid confusion between G-Force, Gauss, and Gram the units have been
renamed to `UNIT_G_FORCE`, `UNIT_GRAM`, and `UNIT_GAUSS`. In addition,
gram now uses the correct symbol `g` and Gauss uses `G`.
2023-02-23 16:44:24 +01:00

43 lines
890 B
C

/*
* Copyright (C) 2016 Freie Universität Berlin
*
* This file is subject to the terms and conditions of the GNU Lesser
* General Public License v2.1. See the file LICENSE in the top level
* directory for more details.
*/
/**
* @ingroup drivers_mma8x5x
* @{
*
* @file
* @brief MMA8x5x adaption to the RIOT actuator/sensor interface
*
* @author Cenk Gündoğan <mail@cgundogan.de>
* @author Hauke Petersen <hauke.petersen@fu-berlin.de>
*
* @}
*/
#include <string.h>
#include <stdio.h>
#include "saul.h"
#include "mma8x5x.h"
static int read_acc(const void *dev, phydat_t *res)
{
mma8x5x_read((const mma8x5x_t *)dev, (mma8x5x_data_t *)res->val);
res->unit = UNIT_G_FORCE;
res->scale = -3;
return 3;
}
const saul_driver_t mma8x5x_saul_driver = {
.read = read_acc,
.write = saul_write_notsup,
.type = SAUL_SENSE_ACCEL,
};