# Copyright (c) 2021 Gunar Schorcht # # This file is subject to the terms and conditions of the GNU Lesser # General Public License v2.1. See the file LICENSE in the top level # directory for more details. # if USEMODULE_VL6180X config VL6180X_RNG_MAX_TIME int "Ranging maximum convergence time [ms]" range 1 63 default 50 depends on USEMODULE_VL6180X_RNG if USEMODULE_VL6180X_ALS config VL6180X_ALS_INT_TIME int "ALS integration time [ms]" range 0 511 default 100 choice VL6180X_ALS_GAIN bool "ALS analogue light channel gain" default VL6180X_ALS_GAIN_1 config VL6180X_ALS_GAIN_1 bool "ALS gain setting 1 (actual analogue gain of 1.01)" config VL6180X_ALS_GAIN_1_25 bool "ALS gain setting 1.25 (actual analogue gain of 1.28)" config VL6180X_ALS_GAIN_1_67 bool "ALS gain setting 1.67 (actual analogue gain of 1.72)" config VL6180X_ALS_GAIN_2_5 bool "ALS gain setting 2.5 (actual analogue gain of 2.60)" config VL6180X_ALS_GAIN_5 bool "ALS gain setting 5 (actual analogue gain of 5.21)" config VL6180X_ALS_GAIN_10 bool "ALS gain setting 10 (actual analogue gain of 10.32)" config VL6180X_ALS_GAIN_20 bool "ALS gain setting 20 (actual analogue gain of 20)" config VL6180X_ALS_GAIN_40 bool "ALS gain setting 40 (actual analogue gain of 40)" endchoice config VL6180X_ALS_LUX_RES int "ALS lux resolution [lux/count*1000]" range 1 320 default 320 help ALS lux resolution is used to convert count values from ambient light sensing to lux values. It is specified as lux/count*1000. The factory calibrated lux resolution is 0.32 lux/count. endif # USEMODULE_VL6180X_ALS config VL6180X_MEAS_PERIOD int "Measurement period in continuous mode [10 ms]" range 0 255 default 20 help The measurement period is defined as multiple of 10 ms. It is used for both range measurements and ambient light sensing (ALS) in continuous mode. The measurement period also controls the measurement mode used after sensor initialization. If the measurement period is 0, the single-shot mode is used for both the range and ALS measurements, and functions vl6180x_rng_start_single and vl6180x_als_start_single have to be used to start a single measurement. Otherwise the continuous mode is used for both measurements which are started immediatly after sensor initialization. if USEMODULE_VL6180X_IRQ choice bool "Ranging interrupt mode" depends on USEMODULE_VL6180X_RNG default VL6180X_RNG_INT_DRDY help Interrupt defines the interrupt that is enabled for ranging. config VL6180X_RNG_INT_DRDY bool "Data Ready" help Interrupt is triggered when new ranging data are ready to be read config VL6180X_RNG_INT_LOW bool "Level Low" help Interrupt is triggered when ranging values are below lower threshold config VL6180X_RNG_INT_HIGH bool "Level High" help Interrupt is triggered when ranging values are above upper threshold config VL6180X_RNG_INT_OUT bool "Out of Window" help Interrupt is triggered when ranging values are below the lower threshold or above the upper threshold (out of threshold window) endchoice config VL6180X_RNG_THRESH_LOW int "Ranging lower threshold [mm]" depends on VL6180X_RNG_INT_LOW || VL6180X_RNG_INT_OUT range 0 255 default 20 help Interrupt is triggered when ranging values are below this threshold config VL6180X_RNG_THRESH_HIGH int "Ranging upper threshold [mm]" depends on VL6180X_RNG_INT_HIGH || VL6180X_RNG_INT_OUT range 0 255 default 90 help Interrupt is triggered when ranging values are above this threshold choice bool "ALS interrupt mode" depends on USEMODULE_VL6180X_ALS default VL6180X_ALS_INT_DRDY help Interrupt defines the interrupt that is enabled for ALS. config VL6180X_ALS_INT_DRDY bool "Data Ready" help Interrupt is triggered when new ALS data are ready to be read config VL6180X_ALS_INT_LOW bool "Level Low" help Interrupt is triggered when ALS values are below lower threshold config VL6180X_ALS_INT_HIGH bool "Level High" help Interrupt is triggered when ALS values are above upper threshold config VL6180X_ALS_INT_OUT bool "Out of Window" help Interrupt is triggered when ALS values are below the lower threshold or above the upper threshold (out of threshold window) endchoice config VL6180X_ALS_THRESH_LOW int "ALS lower threshold [counts]" depends on VL6180X_ALS_INT_LOW || VL6180X_ALS_INT_OUT range 0 65535 default 50 help Interrupt is triggered when ALS values are below this threshold config VL6180X_ALS_THRESH_HIGH int "ALS upper threshold [counts]" depends on VL6180X_ALS_INT_HIGH || VL6180X_ALS_INT_OUT range 0 65535 default 2000 help Interrupt is triggered when ALS values are above this threshold endif # USEMODULE_VL6180X_IRQ endif # USEMODULE_VL6180X