Teufelchen1
96e748d959
sys/phydat: Remove deprecated print function
...
Co-authored-by: Marian Buschsieweke <maribu@users.noreply.github.com>
2024-04-03 15:29:19 +02:00
Marian Buschsieweke
29cfeb752e
sys/phydat: use flash_utils
2023-02-27 12:31:03 +01:00
Marian Buschsieweke
3c287c058d
sys/phydat: Fix unit confusion
...
Previously, `UNIT_G` was used for g-force with the correct symbol `g`,
`UNIT_GR` for gram (as in kilogram) with the incorrect symbol `G` (which
would be correct for Gauss), and `UNIT_GS` for Gauss with symbol `Gs`
(which is an uncommon but correct symbol).
To avoid confusion between G-Force, Gauss, and Gram the units have been
renamed to `UNIT_G_FORCE`, `UNIT_GRAM`, and `UNIT_GAUSS`. In addition,
gram now uses the correct symbol `g` and Gauss uses `G`.
2023-02-23 16:44:24 +01:00
bors[bot]
855dc07b20
Merge #19080
...
19080: sys/phydat: add functions for Unix time conversion to phydat r=benpicco a=silkeh
Co-authored-by: Silke Hofstra <silke@slxh.eu>
2023-01-21 21:45:41 +00:00
Silke Hofstra
26653dd446
sys/phydat: add functions for Unix time conversion to phydat
...
Add functionality for calculating Unix timestamps to phydat.
This allows one to convert dates received from RTCs and the like
to Unix timestamps.
2023-01-21 11:01:42 +01:00
Karl Fessel
af8589059e
sys/includes: replace kernel_defines.h
2022-11-22 13:39:35 +01:00
Lars Pfau
7a94b36430
sys/phydat: fix phydat_to_json dim precondition
2022-05-19 07:29:51 +02:00
chrysn
206bea0a1d
phydat: Add Tesla unit
...
While this is equivalent to the existing Gs (1 T = 10^-4 Gs), this is
the SI (and thus preferred) unit.
2022-01-25 13:46:08 +01:00
Silke Hofstra
5e9b531d33
sys/phydat: clarify use of phydat::scale in phydat_fit
2021-03-04 21:30:18 +01:00
Hauke Petersen
9ad65786dd
sys/phydat: added phydat_to_json converter
2020-05-20 15:29:24 +02:00
Hauke Petersen
3e4229cd31
phydat: add verbose unit_to_str function
2020-05-20 15:29:24 +02:00
Gunar Schorcht
558322bc6f
sys/phydat: add ohm as unit
2020-03-12 08:42:59 +01:00
Michel Rottleuthner
36fca364f8
sys/phydat: add unit for count per cubic meter
2020-02-20 14:26:55 +01:00
61db4d9724
sys/include: fix typos
2019-11-23 22:39:37 +01:00
fabian18
7e8cce875a
drivers/ina3221: Added SAUL integration
2019-11-05 12:37:41 +01:00
Leandro Lanzieri
563a053bc1
Merge pull request #10983 from skullbox305/driver_ph_oem
...
drivers/ph_oem: support for Atlas Scientific pH OEM sensor
2019-09-09 10:18:49 +02:00
Igor Knippenberg
61d0970939
drivers/saul: Added pH
...
- added device class SAUL_SENSE_PH in saul.h
- added stringification SAUL_SENSE_PH in saul_str.c
2019-09-05 12:47:10 +02:00
Benjamin Valentin
e8dc1119b8
sys: make use of ARRAY_SIZE macro
2019-08-06 19:43:54 +02:00
Leandro Lanzieri
afeb5c1e04
sys/phydat: Add capacitance unit (F)
2019-02-15 13:37:45 +01:00
Michel Rottleuthner
61dc1920d3
sys/phydat: add unit for mass concentration (g/m^3)
2019-01-30 13:15:17 +01:00
Marian Buschsieweke
cc0e6dc779
sys/phydat: Added unit Coulomb
2019-01-28 13:33:16 +01:00
Marian Buschsieweke
a04001d781
sys/phydat: Added unit decibel-milliwatts
2018-11-06 11:07:01 +01:00
Marian Buschsieweke
fe46cae00d
sys/phydat: New phydat_fit API
...
The current phydat_fit implementation the following limitations:
- The API is way more complicated to use than needed
- It doesn't perform any rounding
- It uses `long` in a place where actual width (or better range) of the type
is pretty important.
This commit addresses these limitations and uses lookup-tables to reduce the
number of divisions required.
Before this commit code using it looked like this:
``` C
long values[] = { 100000, 2000000, 30000000 };
phydat_t dat = { .scale = 42, .unit = UNIT_V };
phydat_fit(&dat, values[0], 0, phydat_fit(&dat, values[1], 1, phydat_fit(&dat, values[2], 2, 0)));
```
Now it can be used like this:
``` C
int32_t values[] = { 100000, 2000000, 30000000 };
phydat_t dat = { .unit = UNIT_V, .scale = 42 };
phydat_fit(&dat, values, 3);
```
2018-10-24 13:05:51 +02:00
d4bfb0f0a3
sys/phydat: add counts unit
2018-10-15 11:44:04 +02:00
25b90317f3
sys/phydat: add ppb unit support
2018-06-11 15:46:46 +02:00
Joakim Nohlgård
63f49f22d8
sys/phydat: Add phydat_fit
...
Fits larger values into the 16 bit integers used by phydat and update
scale accordingly.
2018-03-22 15:21:01 +01:00
Joakim Nohlgård
7f89435dc7
sys/phydat: Introduce PHYDAT_MIN, PHYDAT_MAX
2018-02-28 08:33:01 +01:00
Joakim Nohlgård
56f44729d7
sys/phydat: rename phydat_scale_to_str -> phydat_prefix_from_scale
...
Correct some outdated documentation and make the name represent what the
function does today.
2018-02-26 15:41:36 +01:00
0fcc7d3834
cleanup: apply headerguard script output
2017-05-24 17:54:02 +02:00
e2e3704973
sys/phydat: adding illuminance unit (Lux)
2016-06-06 11:04:11 +02:00
Hauke Petersen
2a4b7cbc91
sys/phydat: dump function can handle fixed floats
2016-03-29 15:23:04 +02:00
Hauke Petersen
6134dc80fd
sys/phydat: fixed typos in documentation
2015-12-01 14:34:59 +01:00
Hauke Petersen
786895a378
sys: added module for handling physical data
2015-11-30 20:33:53 +01:00