Previously, ztimer would happily set an absolute RTT alarm value that exceeds
RTT's maximum value (though not a longer interval), as the `val` was
simply added to `rtt_get_counter()`.
This commit ensures that the target value wraps around RTT_MAX_VALUE.
Fixes#13920.