The NETOPT_ADDRESS option of the nrf24l01p_ng driver modified the address of pipe 0 but the main listening
address was designed to be the address of pipe 1.
The Silicon Labs Si705x sensors (Si7050/1/3/4/5) are very similar to the
Si7021 sensors featuring only a temperature sensor and no humidity
sensor. The only difference between the Si705x is the temperature
accuracy of the reading, ranging from +/- 0.1 C in the Si7051 to +/- 1 C
in the Si7050.
This patch adds support for this family of sensors extending the
functionality of the existing si70xx driver. Following the style of
other modules, this implements a pseudomodule per supported chip, adding
si7050, si7051, si7053, si7054 and si7055 pseudomodules.
As a minor change this patch also implements the missing
si70xx_get_serial, si70xx_get_id and si70xx_get_revision functions that
were declared in the si70xx.h header but implemented as private
functions. The si70xx_get_id() may be relevant for the application to
know at run time exactly which version of the hardware is installed.
The updated test running with a Si7051 shows the following output, which
seems consistent with the room temperature conditions during the test.
```
make SI70XX_VARIANT=si7051 -C tests/driver_si70xx/ all flash
```
```
SI70XX temperature and humidity sensor test application
Initializing sensor...
[OK]
Found SI7051 sensor, revision 32
temperature: 24.71 C
temperature: 24.69 C
```
tests/driver_ds3231
drivers/ds3231: add alarm support with IRQ
drivers/ds3231: alarm support and documentation
drivers/ds3231: alarm interrupt with mutex
drivers/ds3231: alarm, _unlock function
fixup! drivers/ds3231: add alarm support
The current MODULE_WS281X_ATMEGA only supports ATmega core.
This update Kconfig to select MODULE_WS281X_ATMEGA module by
CPU_CORE_AVR_MEGA instead HAS_ARCH_AVR8.
Signed-off-by: Gerson Fernando Budke <nandojve@gmail.com>
Some periph_rtt implementations do not provide `rtt_set_counter()`. This
adds `periph_rtt_set_counter` as feature to allow testing for its
availability. The feature is provided at CPU level if periph_rtt is
provided by the board for all CPUs implementing `rtt_set_counter()`.
The SAUL implementation of the BMx280 currently returns the pressure in hPa.
The sensor, however, actually reads the pressure in Pa, leading to a
significant loss of precision.
Because the operation range of the BME280 and BMP280 is 300 hPa to 1100 hPa,
we can safely increase the precision by a factor of 10 without risk of overflow.
The only downside is that readings are now presented as `e1 Pa` (eg 10206e1 Pa).
Some periph_rtt implementations do not provide `rtt_set_counter()`. This
adds `periph_rtt_set_counter` as feature to allow testing for its
availability. The feature is provided at CPU level if periph_rtt is
provided by the board for all CPUs implementing `rtt_set_counter()`.